NATURAL VENTILATION ASSESSMENTS

What is it?

Natural Ventilation is the process of supplying and removing air, usually without the use of a fan or other mechanical system. It uses outdoor air flow caused by pressure differences between the building and its surrounding to provide ventilation and space cooling.

Source: HK Building Technology Net, Natural Ventilation, http://gbtech.emsd.gov.hk/english/utilize/natural.html

BREEAM assess indoor air quality with the aim is to recognise and encourage a healthy internal environment through the design, specification and installation of appropriate ventilation, equipment and finishes.

What is it for?

Read more...

The purpose of natural ventilation is to provide fresh air and oxygen to occupants, remove odours and pollutants. It can also help to control internal temperature and humidity.

For assessing Indoor air quality, the testing and measurement of pollutants should be in accordance with the relevant standards, sample measurements should normally be taken from representative habitable or occupied rooms. We are capable of achieving compliance upon spaces with a depth higher than 15m, maintaining good levels of natural ventilation and thermal comfort, by the achievement of higher rates of ventilation to remove short-term odours and prevent overheating.

We can help your dwelling or commercial premises minimize sources of air pollution and the potential for natural ventilation. In case the dwelling has laboratory facilities we can give you recommendations to achieve good indoor air quality.

In ECOstudio XV® LTD we can assess adequate airflow in naturally ventilated and air-conditioned/mechanically ventilated buildings. Recommendations will be given in order to minimize health problems caused by deficient interior air characteristics and to guarantee your design is compliant upon elements stated on BREEAM.

Requirements

MINIMIZING THE SOURCES OF AIR POLLUTION

  • Implement and develop an Indoor Air Quality plan
  • Provide enough fresh air via ventilation pathways to minimize the build-up and recirculation of air pollutants.
  • HVAC systems must incorporate suitable filtration to minimize external air pollution, as defined in BS EN 13779:2007 Annex A3.
  • Areas of the building subject to large and unpredictable or variable occupancy patterns should have carbon dioxide (CO 2 ) or air quality sensors specified, AND:
    • Mechanically ventilated buildings/spaces: sensor(s) are linked to the mechanical ventilation system and provide demand-controlled ventilation to the space.
    • Naturally ventilated buildings/spaces: sensors either have the ability to alert the building owner or manager when CO 2  levels exceed the recommended set point, or are linked to controls with the ability to adjust the quantity of fresh air, i.e. automatic opening windows/roof vents

ADAPTABILITY - POTENTIAL FOR NATURAL VENTILATION

SOURCE: BREEAM HEA-02 INDOOR AIR QUALITY

http://www.breeam.com/BREEAM2011SchemeDocument/content/05_health/hea02.htm